0% found this document useful (0 votes)
37 views3 pages

Contactor 95a 3p 230v Lc1d95p5

This document provides product specifications for a TeSys D contactor with 3 poles rated for 95A AC-3 at voltages less than or equal to 440V. Key details include: - Rated for 95A at less than or equal to 440V AC-3 and 125A at less than or equal to 440V AC-1 - Controls 3 phase motors up to 45kW and single phase motors up to 25kW - Operates on 230V 50Hz control circuit voltage - Includes 1 normally open and 1 normally closed auxiliary contact - Intended applications include motor and resistive load control

Uploaded by

Lucia Trifan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views3 pages

Contactor 95a 3p 230v Lc1d95p5

This document provides product specifications for a TeSys D contactor with 3 poles rated for 95A AC-3 at voltages less than or equal to 440V. Key details include: - Rated for 95A at less than or equal to 440V AC-3 and 125A at less than or equal to 440V AC-1 - Controls 3 phase motors up to 45kW and single phase motors up to 25kW - Operates on 230V 50Hz control circuit voltage - Includes 1 normally open and 1 normally closed auxiliary contact - Intended applications include motor and resistive load control

Uploaded by

Lucia Trifan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product datasheet LC1D95P5

Characteristics TeSys D contactor 3P 95A AC-3 <= 440V - aux


1NO+1NC - coil 230V 50Hz

Price* : 289.76 GBP

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range TeSys
Product name TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-3
AC-4
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 300 V DC for power circuit
<= 1000 V AC 25...400 Hz for power circuit
[Ie] rated operational current 125 A (<= 60 °C) at <= 440 V AC-1 for power circuit
95 A (<= 60 °C) at <= 440 V AC-3 for power circuit
Motor power kW 45 kW at 415...440 V AC 50 Hz AC-3
55 kW at 500 V AC 50 Hz AC-3
45 kW at 660...690 V AC 50 Hz AC-3
45 kW at 380...400 V AC 50 Hz AC-3
45 kW at 1000 V AC 50 Hz AC-3
25 kW at 220...230 V AC 50 Hz AC-3
15 kW at 400 V AC 50 Hz AC-4
Motor power HP (UL / CSA) 20 hp at 200/208 V AC 60 Hz for 3 phases motors
7.5 hp at 115 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
25 hp at 230/240 V AC 60 Hz for 3 phases motors
60 hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type AC 50 Hz
[Uc] control circuit voltage 230 V AC 50 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage Conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal 125 A at <= 60 °C for power circuit
current 10 A at <= 60 °C for signalling circuit
Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947

Oct 8, 2018
1
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A <= 40 °C 1 s power circuit
135 A <= 40 °C 10 min power circuit
400 A <= 40 °C 1 min power circuit
800 A <= 40 °C 10 s power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Associated fuse rating 160 A gG at <= 690 V coordination type 2 for power circuit
200 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance 0.8 mOhm at 50 Hz - Ith 125 A for power circuit
[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Electrical durability 1.2 Mcycles 95 A AC-3 at Ue <= 440 V
1.3 Mcycles 125 A AC-1 at Ue <= 440 V
Power dissipation per pole 7.2 W AC-3
12.5 W AC-1
Safety cover With
Mounting support Plate
Rail
Standards EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
EN/IEC 60947-5-1
Product certifications BV
CCC
CSA
UL
EAC
DNV-GL
Connections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end
Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 2 cable(s) 4...16 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: solid - without cable end
Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: solid - without cable end
Tightening torque Power circuit : 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
Power circuit : 9 N.m - on connector hexagonal 4 mm
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time 20...35 ms closing
6...20 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 10 Mcycles
Operating rate <= 3600 cyc/h at <= 60 °C

Complementary
Coil technology Without built-in suppressor module

2
Control circuit voltage limits 0.3...0.6 Uc drop-out at 55 °C, AC 50 Hz
0.85...1.1 Uc operational at 55 °C, AC 50 Hz
Inrush power in VA 200 VA at 20 °C (cos ϕ 0.75) 50 Hz
Hold-in power consumption in VA 20 VA at 20 °C (cos ϕ 0.3) 50 Hz
Heat dissipation 6...10 W at 50 Hz
Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance > 10 MOhm for signalling circuit

Environment
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -60...80 °C
Permissible ambient air temperature -40...70 °C at Uc
around the device
Operating altitude 3000 m without derating in temperature
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
Shocks contactor open 8 Gn for 11 ms
Vibrations contactor closed 3 Gn, 5...300 Hz
Shocks contactor closed 10 Gn for 11 ms
Height 127 mm
Width 85 mm
Depth 130 mm
Product weight 1.61 kg

Contractual warranty
Warranty period 18 months