Explosion Proof Bals
Explosion Proof Bals
192
back to contents
EX DEVICES < Marking Of
7
7
IP66 through bayonet locks, even while Plug with IP66 in every position 100% backwards compatible with the CES
plugged in series
193
back to contents
EX DEVICES Labelling
of electrical devices in accordance with directive 94/9 EC
(ATEX 96) and IEC 60079-0
• Various versions:
Extra-low voltage, 16A
• Large handle, can be locked in position 0 and 1
• German switch position indicator
• Optimal contact by means of self-cleaning laminated contacts
• Low plugging and pulling forces through floating pins
Various versions
194
back to contents
EX DEVICES FOR ZONE 2 AND 22 For infrequent/brief hazardous explosive atmospheres
Ampere 16 16 16 32 32
Poles 3 4 5 4 5
a 94.0 104.0 104.0 124.0 124.0
b 115.0 125.0 125.0 150.0 150.0
c 105.0 115.0 115.0 135.0 135.0
d 93.0 103.0 103.0 123.0 123.0
e 232.0 248.0 248.0 281.0 281.0
f 164.0 174.0 174.0 204.0 204.0
h 168.0 181.0 181.0 207.0 207.0
Further information at [Link] . Voltages and frequencies not listed here available on request. 195
back to contents
EX DEVICES FOR ZONE 1 AND 21 For occasional hazardous explosive atmospheres
Ampere 16 16 16 32 32
Poles 3 4 5 4 5
a 94.0 104.0 104.0 124.0 124.0
b 115.0 125.0 125.0 150.0 150.0
c 105.0 115.0 115.0 135.0 135.0
d 93.0 103.0 103.0 123.0 123.0
e 232.0 248.0 248.0 281.0 281.0
f 164.0 174.0 174.0 204.0 204.0
h 168.0 181.0 181.0 207.0 207.0
196 Further information at [Link] . Voltages and frequencies not listed here available on request.
back to contents
EX DEVICES FOR ZONE 2 AND 22 For occasional hazardous explosive atmospheres
Plug 3 4 5
110V 230V 400V 500V
• For use in Zone 2 and 22 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
• Low plugging and pulling forces through floating pins 2P+E 3P+E 3P+N+E 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol
g
• Optional auxiliary contacts for control and signalling purposes Ampere Poles 4h 4h 4h 6h 9h 9h 9h 6h 6h 7h 7h 7h Qty each
• IP66 in any application position
• Acc. to EX II 3 G EEx nAC IIC T6 (16A) 16 3 211079 1 310
• Acc. to EX II 3 G EEx nAC IIC T6, T5 (32A) 16 4 211080 1 380
• Temp. -20…+40°C, (-50…+55°C on request)
16 5 211081 1 430
• Cable diameter 8…20 mm (16A)
• Cable diameter 12…28 mm (32A) 32 4 211082 1 500
32 5 211083 1 600
Ampere 16 16 16 32 32
Poles 3 4 5 4 5
A 176.0 176.0 176.0 204.0 204.0
øB 60.0 60.0 60.0 72.0 72.0
øC 43.5 49.0 56.5 57.0 63.4
øD 76.0 89.0 92.0 99.0 102.0
Plug 3 4 5
110V 230V 400V 500V
• For use in Zone 2 and 22 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
• Low plugging and pulling forces through floating pins 2P+E 3P+E 3P+N+E 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol
g
• Optional auxiliary contacts for control and signalling purposes Ampere Poles 4h 4h 4h 6h 9h 9h 9h 6h 6h 7h 7h 7h Qty each
• IP66 in any application position
• Acc. to EX II 3 G EEx nAC IIC T6, T5, T4 (63A) 63 4 211084 1 935
• Acc. to EX II 3 G EEx nAC IIC T6, T5 (125A) 63 5 211085 1 990
• Temp. -20…+40°C, (-50…+55°C on request)
125 4 211086 1 1280
• Cable diameter 24…36 mm (63A)
• Cable diameter 30…50 mm (125A) 125 5 211087 1 1380
Further information at [Link] . Voltages and frequencies not listed here available on request. 197
back to contents
EX DEVICES FOR ZONE 1 AND 21 For occasional hazardous explosive atmospheres
Plug 3 4 5
110V 230V 400V 500V
• For use in Zone 1 and 21 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
• Low plugging and pulling forces through floating pins 2P+E 3P+E 3P+N+E 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol
g
• Optional auxiliary contacts for control and signalling purposes Ampere Poles 4h 4h 4h 6h 9h 9h 9h 6h 6h 7h 7h 7h Qty each
• IP66 in any application position
• Acc. to EX de IIC T6, with intrinsically safe auxiliary contacts Ex de(ia) IIC 16 3 211088 1 420
T6 - gas explosion protection - 16A.
• Acc. to EX tD A21 IP66 - dust explosion protection - 16A 16 4 211089 1 380
• Acc. to EX de IIC T6 T5, with intrinsically safe auxiliary contacts Ex de(ia) 16 5 211090 1 430
IIC T6 T5 - gas explosion protection - 32A.
• Acc. to EX tD A21 IP66 - dust explosion protection - 32A 32 4 211091 1 500
• For temp., see explosion protection details (-50°C on request - 32 5 211092 1 600
with internal lubrication with silicone grease)
• Cable diameter 8…20 mm (16A)/ 12…28 mm (32A)
Ampere 16 16 16 32 32
Poles 3 4 5 4 5
A 176.0 176.0 176.0 204.0 204.0
øB 60.0 60.0 60.0 72.0 72.0
øC 43.5 49.0 56.5 57.0 63.4
øD 76.0 89.0 92.0 99.0 102.0
Plug 3 4 5
110V 230V 400V 500V
• For use in Zone 1 and 21 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
• Low plugging and pulling forces through floating pins 2P+E 3P+E 3P+N+E 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol 3pol 4pol 5pol
g
• Optional auxiliary contacts for control and signalling purposes Ampere Poles 4h 4h 4h 6h 9h 9h 9h 6h 6h 7h 7h 7h Qty each
• IP66 in any application position
• Acc. to EX de IIC T6 T5, with intrinsically safe auxiliary contacts 63 4 211093 1 880
Ex de(ia) IIC T6 T5 - gas explosion protection - 32-125A. 63 5 211094 1 940
• Acc. to EX tD A21 IP66 - dust explosion protection - 32 - 125A
• For temp., see explosion protection details (-50°C on request - with 125 4 211095 1 1280
internal lubrication with silicone grease) 125 5 211096 1 1380
• Cable diameter 24…36 mm (63A)
• Cable diameter 30…50 mm (125A)
198 Further information at [Link] . Voltages and frequencies not listed here available on request.
back to contents
EX DEVICES FOR ZONE 2 AND 22 For infrequent/brief hazardous explosive atmospheres
Ampere 16 16
Poles 2 3
A 140. 0 140.0
øB 53.0 53.0
øC 42.0 42.0
Further information at [Link] . Voltages and frequencies not listed here available on request. 199
back to contents
EX DEVICES FOR ZONE 1, 2 AND For occasional hazardous explosive atmospheres
21, 22
Ampere 16 16
Poles 2 3
A 140.0 140.0
øB 53.0 53.0
øC 42.0 42.0
200 Further information at [Link] . Voltages and frequencies not listed here available on request.
back to contents