Catalog Danfoss Fc302 en
Catalog Danfoss Fc302 en
Intelligence
to empower
your industrial
applications
drives.danfoss.com
Content
Seamlessly into the future............................................................................ 4 Modular simplicity – A, B and C enclosures....................................... 22
Consistently awesome.................................................................................... 5 VLT® Wireless Communication Panel LCP 103.................................. 23
Designed for easy integration in any application.......................... 6 High-power modularity – D, E and F enclosures............................ 24
Designed with fast and easy start-up in mind................................. 7 Extended functionality for high-performance operation
Extensive functionality for high-performance operation.......... 8 – Enclosed Drives............................................................................................... 26
Leveraging digitalization to reduce maintenance costs............ 9 Engineered for cost savings via intelligent heat
Flexible, modular and adaptable. Built to last................................... 10 management, compactness and protection.................................... 28
Stand-alone drives, enclosed drives, modules................................. 12 Ruggedized for extra protection............................................................... 28
Application flexibility to boost your business.................................. 13 Optimize performance and grid protection...................................... 31
Integrated motion controller – for positioning DrivePro® Life Cycle services
and synchronization applications............................................................ 14 Delivering a customized service experience!................................... 32
Increase precision, accuracy and speed............................................... 16 Connection example........................................................................................ 34
Tailored safety....................................................................................................... 17 Technical data....................................................................................................... 35
Achieve maximum availability of your system Electrical data – A, B, and C enclosures................................................. 36
– with condition-based monitoring....................................................... 18 Dimensions enclosure sizes A, B and C................................................. 40
Free to connect.................................................................................................... 20 Ordering typecode for A, B and C enclosures.................................. 41
Customized commissioning experience............................................. 21 Electrical data – D, E and F enclosures.................................................. 42
ar
t-u
intelligent, but at the same time quick
om
p
Awes
Throughout the entire lifecycle of your and easy to install and provides years of
application, the VLT® AutomationDrive reliable operation.
provides benefits that not only save
you time and money, but also help Intelligent operation
In
ility
optimize your process while providing VLT® AutomationDrive has a big brain
ellig
ab
the flexibility and reliability to meet ready to be put to work to control your
en
ail
op
your current and future demands. applications effectively, efficiently and
v
ha era
Hig
reliably.
tion
Awesome versatility
Modular and adaptable, the High availability
VLT® AutomationDrive fits into any Once installed, you can trust Do it differently
environment. It can be relied on to VLT® AutomationDrive to provide Know-how and experience
meet all your needs whether you have troublefree operation. New intelligent Proven quality
a single application or a variety of maintenance features and a range of
DrivePro® services
different ones. DrivePro® services proactively improve
productivity, performance and uptime.
Its cutting-edge thermal design
and unique back-channel cooling
for drives above 90 kW make
VLT® AutomationDrive one of the
most compact and cost-efficient
drives in the market.
Application flexibility
When you have a variety of
applications, it’s best to select an AC
drive that you can count on to meet
all your needs. Whether operating
pumps, conveyors, palletizers or
material treatment equipment, the VLT®
AutomationDrive delivers the optimum
control you want for reliable operation,
all day long.
6 DKDD.PB.302.B4.02 | Content |
5
Designed with fast Simple start-up
| Content | DKDD.PB.302.B4.02 7
5
Intelligent operation Extensive functionality for
high-performance operation
The VLT® AutomationDrive FC 300 Series is installed in a
wide variety of demanding applications and environments.
Regardless of your application’s needs, you can count on
the VLT® AutomationDrive to deliver the capabilities for
long, worry-free operation in even the most sensitive of
environments.
8 DKDD.PB.302.B4.02 | Content |
5
Leveraging digitalization Optimized
performance
to reduce maintenance costs
Unplanned downtime can be costly – both in terms of
maintenance and lost production. Enhancements in the
VLT® AutomationDrive provide more information about
your devices and their performance, and a range of services
optimizes their availability.
| Content | DKDD.PB.302.B4.02 9
Flexible, modular and adaptable
Built to last
A VLT® AutomationDrive is built on a flexible, modular Speaks your language
design to provide an extraordinarily versatile motor When it comes to working with
control solution. The drive is equipped with a wide range advanced technologies, such as AC
of industry features that enable optimal process control, drives, it is fairly easy to feel lost while
navigating through hundreds of
higher quality output and reduce costs related to spare parameters. Using a graphical interface
parts and service. makes this process much easier;
especially when it lists parameters
in your native language. As many as
Free to equip motor and remain confident that the 28 language options are available,
The VLT® AutomationDrive can system will perform to the highest including several Cyrillic, Arabic (right
optimally control nearly all standard possible standards. to left) and Asian options.
industrial motor technologies,
including Asynchronous, IPM, SPM, As an independent manufacturer of AC Additionally, the ability to save up
Synchronous Reluctance and PM drive solutions, you can count on to 50 user-selectable parameters
assisted Synchronous Reluctance Danfoss to support all commonly used further simplifies interactions with key
motors. This means that system motor types and foster ongoing parameter settings for your unique
designers, OEMs and end users are free development as new technologies application.
to connect the drive to their selected emerge.
380-500 V
High overload
400 V...................1.3-1460 A IN, 0.37-800 kW,
460 V....................1.2-1380 A IN, 0.5-1200 Hp
Normal overload
400 V.................1.3-1720 A IN, 0.37-1000 kW
Choose the adequate performance level 460 V....................1.2-1530 A IN, 0.5-1350 Hp
Special needs require special features and performance
525-600 V
High overload
FC 301 FC 302 575 V..............................1.7-100 A IN, 1-100 Hp
Power range [kW] 200-240 V 0.25-37 0.25-150
Power range [kW] 380-(480) 500 V 0.37-75 (480 V) 0.37-800 (500 V) Normal overload
Power range [kW] 525-600 V – 0.75-75 575 V..............................1.7-131 A IN, 1-120 Hp
Power range [kW] 525-690 V – 1.1-1200
Flux vector control – n 525-690 V
25/50m (A1 only), High overload
Cable length – screened/unscreened 150/300 m
50/75m
575 V....................1.6-1260 A IN, 1.5-1350 Hp
Permanent magnet motor operation – n
690 V....................1.6-1260 A IN, 1.1-1200 kW
(w/wo feedback)
Safety function Safe Torque Off (STO – EN 61800-5-2) Optional (A1 only) n
Applications Industries
Water and Wastewater
Material handling
Elevators and
Refrigeration
Escalators
Chemical
Metals
Textile
HVAC
Pumps
Fans
Compressors
Conveyors
Winding, unwinding
Drilling
Propulsion, thrusters
Winches
Positioning, synchronization
With touch probe positioning, the drive starts moving forward from the starting
Synchronizing position of 2000, detects the touch probe sensor and moves a distance of 1000
forward from the position of the touch probe sensor.
In synchronizing mode, the drive fol-
lows the position of a master; multiple
drives can follow the same master. The Fig. 3. IMC supports 3 positioning modes
master signal can be an external signal,
for example, from an encoder, a virtual
master signal generated by a drive or
master positions transferred by fieldbus. the machine after power up. There are
Gear ratio and position offset is adjust- several home functions with and with-
able by parameter. out sensor to choose from. The home
synchronizing function can be used to
continuously realign the home position
Homing during operation when there is some
With sensorless control and closed sort of slip in the system. For example
loop control with an incremental in case of sensorless control with an
encoder, homing is required to create induction motor or in case of slip in the
a reference for the physical position of mechanical transmission.
Before
Quick commissioning
Parameter configuration is fully
Contactors
integrated into the VLT® Motion
Actuator
Safety Control Tool MCT 10 and enables
module simple start-up and easy maintenance.
Visual instructions in MCT 10 ensure
AC drive both fault-free wiring and that safety
without STO parameters are correctly transferred
from the PC to the drive.
Feature Benefit
– Reduced total cost of installation
– Condition-based maintenance can be
performed also when installation is off-line
Condition-based monitoring function or not connected to the internet
embedded in the drive – Condition-based maintenance can be
performed without additional components,
such as PLCs or SCADA systems
– Ability to detect and react to early faults in the
Motor-stator-winding monitoring motor stator winding before the fault develops
into a crippling failure
– Ability to quickly detect and react to signs
Vibration monitoring in application of mechanical misalignment, wear-out and
looseness
– Process optimization/maximized efficiency
thanks to ability to compare actual system
Load envelope performance with baseline data and trigger
maintenance actions
20 DKDD.PB.302.B4.02 | Content |
Customized commissioning experience
The VLT® Motion Control Tool MCT 10 VLT® Software Customizer
is an interactive tool for quick and easy VLT® Software Customizer allows you
online/offline configuration of a VLT® to customize the commissioning
drive or soft starter using a PC. You experience to best fit your needs. It is
can also use the tool to configure the a tool that enables you to simply and
communication network and to back quickly create and test your desired
up all your relevant parameter settings. setup using the simulator before
With MCT 10, you can control and uploading it to a real drive.
configure your system simultaneously
and monitor your entire system more The VLT® Software Customizer consists
effectively for faster monitoring, of three main features:
diagnosis, troubleshooting (alarms/
warnings) and better preventive
SplashScreen allows you to create
maintenance. Starting with version a custom splash screen for when the
4.00, MCT 10 includes even more drive starts up. You can use the built-
features that enhance usability. in editor to create an image from
blank or import an existing image
from a library or from your computer
Status plug-in and adapt it to the VLT®.
The readouts for various status and
control words, relay inputs and outputs
InitialValues allows you to set a
that are available over the fieldbus new default value for virtually any
have been greatly improved. We have parameter.
combined these signals into a single
plug-in that shows you much more
SmartStart allows you to create
information. You’ll be able to see right a custom start-up wizard to go
away if a certain relay or bit is on or off, through exactly the parameters you
and what exact command the drive has need.
been configured with, saving you time.
Motor plug-in
The motor plug-in makes it easier to
select the needed motor type and to
parameterize the drive accordingly.
Simply select the required motor type,
and the corresponding parameters
are listed together with a description
guiding you on how to set the correct
value. The motor types supported by
the motor plug-in are:
Asynchronous
PM, non-salient SPM
PM, salient IPM
Synchronous Reluctance (SynRM)
8
2
7
8
5
3
2
9
10
9. 24 V supply or RTC
A 24 V supply option to keep the VLT® Wireless Communication Panel LCP 103
control section and any installed
option functioning during power The VLT® Wireless Communication
failure. An extended version Panel LCP 103 (8) communicates
combines a Real-time Clock with with MyDrive® Connect – an app
a battery in one D-option. which can be downloaded to iOS-
and Android-based smart devices.
10. Mains switch
This switch interrupts the mains MyDrive® Connect offers full access
supply and has a free useable to the drive making it easier to
auxiliary contact. perform commissioning, operation,
monitoring and maintenance tasks.
Safety Utilizing the active point-to-point
Extended range of integrated wireless connection, maintenance
functional safety. Please see chapter personnel can receive real-time error
“Tailored safety” on page 17. messages via the app to ensure a
quick response to potential issues
and reduce downtime.
12
Efficiency is vital 4
for high-power drives
Efficiency is essential in the design 5 10
of the high-power VLT® drive series.
Innovative design and exceptionally 14
high-quality components have resulted 6
in unsurpassed energy efficiency. 7
11
13
VLT® drives pass more than 98% of
the supplied electrical energy on to
the motor. Only 2% or less is left in
the power electronics as heat to be
removed.
8
Safety
Extended range of integrated
functional safety. Please see chapter
“Tailored safety” on page 17. 9
15
A B C
. Door-mounted control
1 3. Back-channel cooling 6. Bottom entry establish-
compartment assembly for power options ment
separate from the main power ensures utilization of the drive’s ensures IP54/NEMA12 connections
terminals ensures safe accessibility back-channel cooling concept in of the enclosed drive mains
to control terminals, also during the cabinet and efficient cooling terminals to the power supply.
operation of the drive. of the integrated selectable power
options. 7. Mains reactor assembly
2. VLT® AutomationDrive of the selectable passive harmonic
high-power drive in enclosure 4. Mains contactor filter ensures absolute minimum
size D or E, with selectable control is a selectable mains power option. harmonics content of the mains
options. currents: THDi <5%.
5. Mains switch disconnect
is a selectable mains power option.
12
13 11
1 4
3
6
14
The AC drives are available in a broad contaminants. At the same time, it In daily use, the benefits are equally
range of enclosure sizes and protection removes heat efficiently which helps clear as the energy consumption
ratings from IP20 to IP66 to enable to prolong product life, increase related to cooling can be reduced
easy installation in all environments: the overall availability of the system significantly. This means that designers
mounted in panels, switch rooms or and reduce faults related to high can reduce the size of the air
as stand-alone units in the production temperatures. conditioning system, or even eliminate
area. it entirely.
For example, by exhausting heat
directly outside, it is possible to reduce
Cost-saving heat management the size of the cooling system in the Coated circuit boards
In AC drives, there is total separation panel or switch room. This can be The AC drive conforms as standard to
between the back-channel cooling achieved with Danfoss’ extremely class 3C3 (IEC 60721-3-3) to ensure long
air and the internal electronics. efficient back-channel cooling concept, lifetime even in harsh environments.
This separation greatly reduces the allowing heat to be vented outside the
airflow over the sensitive electronics, control room.
minimizing the exposure to
Ruggedized for
extra protection
In order to reduce the potential Spark-free design
negative effects of vibration, the drives The VLT® drives conform to the Limited
have been ‘ruggedized’. It is a process Explosion Risk requirements in The
that ensures that critical components European Agreement concerning the
on the PCB have increased protection, International Carriage of Dangerous
significantly reducing the risk of Goods by Inland Waterways, as they do
malfunction while at sea. not create any sparks durings normal
operation and the temperature does
The printed circuit boards in the drives not exceed 200 °C.
are also all coated in accordance with
IEC 60721-3-3 class 3C3, providing
additional protection against moisture
and dust.
Reliable operation at
engine room temperatures
up to 55 °C
VLT® drives can operate at full load in
engine rooms with 50 °C temperature
and 55 °C at reduced power close to,
for example, pumps and thrusters.
There is no need for installation in air-
conditioned control rooms with long
motor cables.
90%
reduction
in investment for air
cooling systems
Panel-through cooling
An accessory mounting kit for small and
mid-range drives enables heat losses to be
directed directly outside the panel room.
A built-in, scalable RFI filter minimizes These built-in components save cabinet space, as
electromagnetic interference, and the integrated they are integrated in the drive from the factory.
DC link chokes reduce the harmonic distortion in Efficient EMC mitigation also enables the use of
the mains network, in accordance with cables with smaller cross-sections, which reduces
IEC 61000-3-12. Furthermore, they increase the installation costs.
VLT® Advanced Active Filter AAF allows the drive to be installed in a
VLT® Low Harmonic Drives central control room, away from the -300
VLT® 12-pulse Drives application without affecting motor
8 16 24 32 [ms]
performance.
Provide extra motor protection with:
Harmonic distortion
VLT® Sine-wave Filter Electrical interference reduces e fficiency and risks
VLT® dU/dt Filter harming equipment.
VLT® Common Mode Filters
0
[V]
-150
-300
8 16 24 32 [ms]
Optimized harmonic performance
Efficient harmonic mitigation protects electronics
and increases efficiency.
Compliance 1) n n n
ACTIVE
TED
NE W
MI
LI
IN A
C TIV E
DrivePro® Upgrade
Maximize your AC drive investment
Use an expert to replace parts or software
in a running unit, so your drive is always up-
DrivePro® Upgrade
to-date. You receive an on-site evaluation,
an upgrade plan and recommendations for
future improvements.
To learn which products are available in your region, please reach out
to your local Danfoss Drives sales office or visit our website
http://drives.danfoss.com/danfoss-drives/local-contacts/
130BC931.10
91 (L1) (U) 96
3 Phase 92 (L2) (V) 97
power
input 93 (L3) (W) 98
95 PE (PE) 99
Motor
ON
+10Vdc relay1
ON=0/4-20mA
0/4-20 mA S202 03
OFF=0/-10Vdc -
1 2
0/-10Vdc - +10Vdc
ON
54 (A IN) 240Vac, 2A
+10Vdc 02
0/4-20 mA
55 (COM A IN) 01
* relay2
12 (+24V OUT) 06
240Vac, 2A
13 (+24V OUT) P 5-00 05
400Vac, 2A
24V (NPN)
18 (D IN) 04
0V (PNP)
24V (NPN)
19 (D IN) 0V (PNP) (COM A OUT) 39 Analog Output
0/4-20 mA
(A OUT) 42
20 (COM D IN)
24V (NPN)
27 (D IN/OUT) 0V (PNP) S801
24V ON=Terminated
1 2
ON
OFF=Open
0V 5V
* 24V (NPN)
29 (D IN/OUT) 0V (PNP)
24V
S801 0V
0V
RS-485 RS-485
(N RS-485) 69
24V (NPN) Interface
32 (D IN) 0V (PNP) (P RS-485) 68
24V (NPN) **
33 (D IN) 0V (PNP) (COM RS-485) 61
: Chassis
* : Earth
37 (D IN)
A = Analog, D = Digital This diagram shows a typical installation There are 6 digital inputs to be
* Terminal 37 (optional) is used for Safe Torque of the VLT® AutomationDrive. Power connected to terminals 18, 19, 27, 29,
Off. For Safe Torque Off installation instructions, is connected to the terminals 91 (L1), 32, and 33. Two digital input/output
refer to the Safe Torque Off Operating
Instructions for Danfoss VLT® Frequency 92 (L2) and 93 (L3) and the motor is terminals (27 and 29) can be set up
Converters. Terminal 37 is not included in FC connected to 96 (U), 97 (V) and 98 (W). as digital outputs to show an actual
301 (except enclosure type A1). Relay 2 and
terminal 29 have no function in FC 301. status or warning or can be used as a
** Do not connect cable screen. Terminals 88 and 89 are used for load pulse reference signal. The terminal 42
sharing between drives. Analog inputs analog output can show process
can be connected to the 53 (V or mA), values such as 0 - Imax.
and for 54 (V or mA) terminals.
On the 68 (P+) and 69 (N-) terminals’
These inputs can be set up as either RS 485 interface, the drive can be
reference, feedback or thermistor controlled and monitored via serial
inputs. communication.
Agency approvals
FC-302 Con. IN Inter. IMAX kW @ 208 V Hp @ 230 V [A] [W] Chassis Type 1 Type 12 Type 4X
(60 s)
PK25 1.8 2.9 0.25 0.34 1.6 21 A1*/A2 A2 A4/A5 A4/A5
PK37 2.4 3.8 0.37 0.5 2.2 29 A1*/A2 A2 A4/A5 A4/A5
PK55 3.5 5.6 0.55 0.75 3.2 42 A1*/A2 A2 A4/A5 A4/A5
PK75 4.6 7.4 0.75 1 4.1 54 A1*/A2 A2 A4/A5 A4/A5
P1K1 6.6 10.6 1.1 1.5 5.9 63 A1*/A2 A2 A4/A5 A4/A5
P1K5 7.5 12 1.5 2 6.8 82 A1*/A2 A2 A4/A5 A4/A5
P2K2 10.6 17 2.2 3 9.5 116 A2 A2 A4/A5 A4/A5
P3K0 12.5 20 3 4 11.3 155 A3 A3 A5 A5
P3K7 16.7 26.7 3.7 5 15 185 A3 A3 A5 A5
P5K5 24.2 38.7 5.5 7.5 22 239 B3 B1 B1 B1
P7K5 30.8 49.3 7.5 10 28 371 B3 B1 B1 B1
P11K 46.2 73.9 11 15 42 463 B4 B2 B2 B2
P15K 59.4 89.1 15 20 54 624 B4 C1 C1 C1
P18K 74.8 112 18.5 25 68 740 C3 C1 C1 C1
P22K 88 132 22 30 80 874 C3 C1 C1 C1
P30K 115 173 30 40 104 1143 C4 C2 C2 C2
P37K 143 215 37 50 130 1400 C4 C2 C2 C2
*A1 enclosure is only available as FC 301
FC-302 Con. IN Inter. IMAX kW @ 208 V Hp @ 230V [A] [W] Chassis Type 1 Type 12 Type 4X
(60 s)
PK25 1.8 2.9 0.25 0.34 1.6 21 A1*/A2 A2 A4/A5 A4/A5
PK37 2.4 3.8 0.37 0.5 2.2 29 A1*/A2 A2 A4/A5 A4/A5
PK55 3.5 5.6 0.55 0.75 3.2 42 A1*/A2 A2 A4/A5 A4/A5
PK75 4.6 7.4 0.75 1 4.1 54 A1*/A2 A2 A4/A5 A4/A5
P1K1 6.6 10.6 1.1 1.5 5.9 63 A1*/A2 A2 A4/A5 A4/A5
P1K5 7.5 12 1.5 2 6.8 82 A1*/A2 A2 A4/A5 A4/A5
P2K2 10.6 17 2.2 3 9.5 116 A2 A2 A4/A5 A4/A5
P3K0 12.5 20 3 4 11.3 155 A3 A3 A5 A5
P3K7 16.7 26.7 3.7 5 15 185 A3 A3 A5 A5
P5K5 30.8 33.9 7.5 10 28 310 B3 B1 B1 B1
P7K5 46.2 50.8 11 15 42 514 B3 B1 B1 B1
P11K 59.4 65.3 15 20 54 602 B4 B2 B2 B2
P15K 74.8 82.3 18.5 25 68 737 B4 C1 C1 C1
P18K 88 96.8 22 30 80 845 C3 C1 C1 C1
P22K 115 127 30 40 104 1140 C3 C1 C1 C1
P30K 143 157 37 50 130 1353 C4 C2 C2 C2
P37K 170 187 45 60 154 1636 C4 C2 C2 C2
*A1 enclosure is only available as FC 301
FC-302 Con. IN Inter. IMAX kW @ 575 V Hp @ 575 V [A] @ 575 V [W] Chassis Type 1 Type 12 Type 4X
(60 s)
PK75 1.7 2.7 0.75 1 1.7 35 A3 A3 A5 A5
P1K1 2.4 3.8 1.1 1.5 2.4 50 A3 A3 A5 A5
P1K5 2.7 4.3 1.5 2 2.7 65 A3 A3 A5 A5
P2K2 3.9 6.2 2.2 3 4.1 92 A3 A3 A5 A5
P3K0 4.9 7.8 3 4 5.2 122 A3 A3 A5 A5
P4K0 6.1 9.8 4 5 5.8 145 A3 A3 A5 A5
P5K5 9 14.4 5.5 7.5 8.6 195 A3 A3 A5 A5
P7K5 11 17.6 7.5 10 10.4 261 A3 A3 A5 A5
P11K 18 29 11 15 16 220 B3 B1 B1 B1
P15K 22 35 15 20 20 300 B3 B1 B1 B1
P18K 27 43 18.5 25 24 370 B4 B2 B2 B2
P22K 34 54 22 30 31 440 B4 B2 B2 B2
P30K 41 62 30 40 37 600 B4 C1 C1 C1
P37K 52 78 37 50 47 740 C3 C1 C1 C1
P45K 62 93 45 60 56 900 C3 C1 C1 C1
P55K 83 125 55 75 75 1100 C4 C2 C2 C2
P75K 100 150 75 100 91 1500 C4 C2 C2 C2
FC-302 Con. IN Inter. IMAX kW @ 575 V Hp @ 575 V [A] @ 575 V [W] Chassis Type 1 Type 12 Type 4X
(60 s)
PK75 1.7 2.7 0.75 1 1.7 35 A3 A3 A5 A5
P1K1 2.4 3.8 1.1 1.5 2.4 50 A3 A3 A5 A5
P1K5 2.7 4.3 1.5 2 2.7 65 A3 A3 A5 A5
P2K2 3.9 6.2 2.2 3 4.1 92 A3 A3 A5 A5
P3K0 4.9 7.8 3 4 5.2 122 A3 A3 A5 A5
P4K0 6.1 9.8 4 5 5.8 145 A3 A3 A5 A5
P5K5 9 14.4 5.5 7.5 8.6 195 A3 A3 A5 A5
P7K5 11 17.6 7.5 10 10.4 261 A3 A3 A5 A5
P11K 22 24 15 20 20 300 B3 B1 B1 B1
P15K 27 30 18.5 25 24 370 B3 B1 B1 B1
P18K 34 37 22 30 31 440 B4 B2 B2 B2
P22K 41 45 30 40 37 600 B4 B2 B2 B2
P30K 52 57 37 50 47 740 B4 C1 C1 C1
P37K 62 68 45 60 56 900 C3 C1 C1 C1
P45K 83 91 55 74 75 1100 C3 C1 C1 C1
P55K 100 110 75 100 91 1500 C4 C2 C2 C2
P75K 131 144 90 120 119 1800 C4 C2 C2 C2
Height 10.6 14.8 10.6 14.8 15.4 16.6 18.9 25.6 15.8 20.5 26.8 30.4 21.7 26
Height with decoupling plate 14.8 – 14.8 – – – – – 16.6 23.5 – – 24.8 31.5
Width 3.6 3.6 5.2 5.2 7.9 9.6 9.6 9.6 6.5 9.1 12.2 14.6 12.2 14.6
Width with one C option 5.2 5.2 6.7 6.7 – 9.6 9.6 9.6 8.1 9.1 12.2 14.6 12.2 14.6
[in]
Width with two C options 6 6 7.5 7.5 – 9.6 9.6 9.6 8.9 9.1 12.2 14.6 12.2 14.6
Depth 8.1 18.2 8.1 8.2 6.9 7.9 10.3 10.3 9.8 9.6 12.3 13.2 13 13
Depth with mains disconnect – – – – 8.2 8.9 11.4 11.5 – – 13.6 14.9 – –
Depth with A, B option 8.7 8.8 8.7 8.8 6.9 7.9 10.3 10.3 10.4 9.6 12.3 13.2 13 13
[lb] Weight 10.8 11.7 14.6 15.5 21.5 31.5 50.7 59.6 26.5 52 99.3 143.3 77.2 110.2
FC- – – – – – – – – – – – – – – – CX – – XX –
Height 35.5 43.6 35.8 39.6 44.2 50.0 52.1 65.5 77.9 89.9
[in] Width 12.8 12.8 19.8 9.9 14.8 13.8 12.8 12.8 16.5 16.5
Depth 14.9 14.9 14.8 14.8 14.8 14.8 15.0 15.0 15.2 16.0
[lb] Weight 136.7 275.6 136.7 238.1 275.6 394.6 218.3 282.2 407.9 511.5
(1)
Dimensions with regeneration or load share terminals
(2)
D5h is used with disconnect and/or brake chopper options
(3)
D6h is used with contactor and/or circuit breaker options
(4)
D7h is used with disconnect and/or brake chopper options
(5)
D8h is used with contactor and/or circuit breaker options
D3h/D4h E1h F
FC- – – – – – – – – – – – – – – – CX – – XX –
[1] Application (character 4-6) IP21 / Type 1 – Stainless steel back channel VLT® 12-Pulse, encl. sizes F8, F9, F10, F11, F12, F13
C2M
302 VLT® AutomationDrive FC 302 + mains shield B2 12-Pulse with Class A2 RFI
[2] Power size (character 7-10) IP21 / Type 1 – Stainless steel back channel B4 12-Pulse with Class A1 RFI
C2H + space heater
N55K 55 kW / 75 Hp BE 12-Pulse with RCD / A2 RFI
IP21 / Type 1 + cabinet light
N75K 75 kW / 100 Hp L2A BF 12-Pulse with RCD / A1 RFI
+ 115 V power outlet
N90K 90 kW / 125 Hp BG 12-Pulse with IRM / A2 RFI
IP21 / Type 1 + cabinet light
L2X
N110 110 kW / 150 Hp + 230 V power outlet BH 12-Pulse with IRM / A1 RFI
N132 132 kW / 200 Hp IP21 / Type 1 + space heater + cabinet light [6] Braking and safety (character 18)
R2A
N160 160 kW / 250 Hp + 115 V power outlet X No brake IGBT
N200 200 kW / 300 Hp IP21 / Type 1 + space heater + cabinet light B Brake IGBT
R2X + 230 V power outlet
N250 250 kW / 350 Hp Safe Torque Off with Pilz Safety Relay
IP21 / Type 1 – Stainless steel back channel C
C2E (enclosure sizes F1, F2, F3, F4)
N315 315 kW / 450 Hp + Cooling out the back
P315 315 kW / 450 Hp Safe Torque Off with Pilz Safety Relay
IP54 / UL Type 12 enclosures D and brake IGBT
N355 355 kW / 500 Hp E54 IP54 / Type 12 (enclosure sizes F1, F2, F3, F4)
P355 355 kW / 500 Hp E5M IP54 / Type 12 + mains shield Safe Torque Off with Pilz Safety Relay and
N400 400 kW / 550 Hp E regeneration terminals
IP54 / Type 12, NEMA 3R ready – Stainless steel (enclosure sizes F1, F2, F3, F4)
E5S
P400 400 kW / 550 Hp screws + space heater (D1h, D2h frames)
N450 450 kW / 600 Hp H54 IP54 / Type 12 + space heater + thermostat T Safe Torque Off without brake
P450 450 kW / 600 Hp C54 IP54 / Type 12 – Stainless steel back channel R Regeneration terminals (enclosure sizes D & F)
N560 560 kW / 750 Hp IP54 / Type 12 – Stainless steel back channel Enclosure sizes F3, F4
C5H + space heater
P560 560 kW / 750 Hp IEC Emergency Stop Pushbutton
M
IP54 / Type 12 + cabinet light (includes Pilz Relay)
N630 630 kW / 900 Hp L5A
+ 115 V power outlet
IEC Emergency Stop Pushbutton with brake
P630 630 kW / 900 Hp N IGBT and brake terminals
IP54 / Type 12 + cabinet light
L5X (includes Pilz Safety Relay)
N710 710 kW / 1000 Hp + 230 V power outlet
P710 710 kW / 1000 Hp IP54 / Type 12 + space heater + cabinet light IEC Emergency Stop Pushbutton with
R5A
N800 800 kW / 1200 Hp + 115 V power outlet P regeneration terminals
(includes Pilz Safety Relay)
P800 800 kW / 1200 Hp IP54 / Type 12 + space heater + cabinet light
R5X + 230 V power outlet [7] LCP display (character 19)
P900 900 kW / 1250 Hp
[5] R
FI filter, terminal and monitoring options X Blank faceplate, no LCP installed
P1M0 1.0 MW / 1350 Hp – EN/IEC 61800-3 (character 16-17) N VLT® Control Panel LCP 101 (Numerical)
P1M2 1.2 MW / 1600 Hp H2 RFI filter, Class A2 (C3) G VLT® Control Panel LCP 102 (Graphical)
[3] AC mains voltage (character 11-12)
RFI filter, Class A1 (C2) W VLT® Wireless Communication Panel LCP 103
H4
T5 3 x 380-500 V AC (Enclosure sizes D and F only)
Enclosure size D and E, IP21/IP54 only
3 x 525-690 V AC IRM for IT mains with Class A2 RFI
T7 HG J No Local Control Panel + USB through door
690 V kW. See manuals for 575 V Hp (Enclosure sizes F1, F2, F3, F4)
[4] IP/UL protection ratings (character 13-15) RCD for TN/TT mains with Class A2 RFI Graphical Local Control Panel (LCP 102)
HE L
(Enclosure sizes F1, F2, F3, F4) + USB through door
IP20 Chassis enclosures
HX No RFI filter Numerical Local Control Panel (LCP 101)
E20 IP20 / Chassis K + USB through door
E2S IP20 / Chassis (D3h enclosure) RCD for TN/TT mains and Class A1 RFI
HF [8] PCB coating – IEC 721-3-3 (character 20)
(Enclosure sizes F1, F2, F3, F4)
C20 IP20 / Chassis – Stainless steel back channel X Standard coated PCB Class 3C2
IRM for IT mains and Class A1 RFI
IP20 / Chassis – Stainless steel back channel HH
C2S (Enclosure sizes F1, F2, F3, F4) C Coated PCB Class 3C3
(D3h enclosure)
VLT® Low Harmonic Drive R Coated PCB Class 3C3 + ruggedized
IP21 / UL Type 1 enclosures
VLT® Low Harmonic Drive, active filter [9] Mains input (character 21)
E21 IP21 / Type 1 N2 based with Class A2 RFI X No mains option
E2M IP21 / Type 1 + mains shield
VLT® Low Harmonic Drive, active filter 7 Fuses
N4
E2D IP21 / Type 1 (D1h, D5h, D6h enclosures) based with Class A1 RFI
Fuses and load sharing terminals
H21 IP21 / Type 1 + space heater A (enclosure sizes D/IP20 and F3, F4, F9, F11,
C21 IP21 / Type 1 – Stainless steel back channel F14, F18 only)
FC- – – – – – – – – – – – – – – – CX – – XX –
Load sharing terminals L 5 A 24 V supply + common motor terminals [18] C-option software (character 36-37)
D (enclosure sizes D/IP20 and F3, F4, F9, F11, F14, No software option
External temperature monitoring + common
F18 only) M Note: C4 option in [16] selected with no motion
motor terminals XX
Mains disconnect + fuse software in [18] will require programming by
3 5 A 24 V supply + external temperature qualified individual
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18) N monitoring + common motor terminals
4 Mains contactor + fuse (enclosure size D) VLT® Synchronizing Controller MCO 350
[12] Special version (character 24-27) 10 (must select C4 in position [16])
Mains disconnect, fuse and load sharing SXXX Latest released standard software
5 VLT® Positioning Controller MCO 351
(Not available for enclosure size F18) 11
S067 Integrated Motion Control (must select C4 in position [16])
Mains disconnect + contactor + fuse
E LX1X Condition monitoring [19] D-option (character 38-39)
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
[13] LCP language (character 28) DX No DC input installed
Circuit breaker + fuse
J (enclosure sizes D, E and F3, F4, F9, F11, F14, F18) Standard language package including D0 VLT® 24 V DC Supply Option MCB 107
X English, German, French, Spanish, Danish, D1 VLT® Real-time Clock Option MCB 117
Mains circuit breaker, contactor and fuses Italian, Finnish and others
F (enclosure sizes F3, F4, F9, F11, F14, F18)
Contact factory for other language options Please beware that not all combinations are possible.
Mains disconnect, contactor, load sharing Find help configuring your drive with the online
G terminals and fuses [14] A-options: Fieldbus (character 29-30) configurator found under: driveconfig.danfoss.com
(enclosure sizes F3, F4, F9, F11, F14, F18)
AX No option
Mains circuit breaker, contactor, load sharing A0 VLT® PROFIBUS DP MCA 101
H terminals and fuses
(enclosure sizes F3, F4, F9, F11, F14, F18) A4 VLT® DeviceNet MCA 104
A6 VLT® CANopen MCA 105
Mains circuit breaker, load share and fuses
K (enclosure sizes F3, F4, F9, F11, F14, F18) AT VLT® 3000 PROFIBUS Converter MCA 113
Cable connection cabinet AU VLT® 5000 PROFIBUS Converter MCA 114
T (enclosure size D5h/D7h only)
AL VLT® PROFINET MCA 120
Cable connection cabinet and fuse AN VLT® EtherNet/IP MCA 121
W (enclosure size D5h/D7h only)
AQ VLT® Modbus TCP MCA 122
[10] Hardware option A (character 22)
AY VLT® POWERLINK MCA 123
X Standard cable entries
A8 VLT® EtherCAT MCA 124
Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18
AV VLT® 5000 DeviceNet Converter MCA 194
E 30 A fuse protected power terminals
[15] B-options (character 31-32)
30 A fuse protected power terminals and
F BX No application option
2.5-4 A manual motor starter
BK VLT® General Purpose MCB 101
30 A fuse protected power terminals and
G 4-6.3 A manual motor starter BR VLT® Encoder Input MCB 102
30 A fuse protected power terminals and BU VLT® Resolver Input MCB 103
H 6.3-10 A manual motor starter
BP VLT® Relay Option MCB 105
30 A fuse protected power terminals and BZ VLT® Safety PLC I/O MCB 108
J 10-16 A manual motor starter
B2 VLT® PTC Thermistor Card MCB 112
K Two 2.5-4 A manual motor starters
B4 VLT® Sensor Input Card MCB 114
L Two 4-6.3 A manual motor starters
B5 VLT® Programmable I/O MCB 115
M Two 6.3-10 A manual motor starters
B6 VLT® Safety Option MCB 150 TTL
N Two 10-16 A manual motor starters
B7 VLT® Safety Option MCB 151 HTL
[11] H
ardware option B (character 23)
B8 VLT® Safety Option MCB 152 PROFIsafe STO
X No adaptation
[16] C0-option (character 33-34)
Heat sink access panel
Q CX No option
(enclosure size D and E only)
Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18 C4 VLT® Motion Control MCO 305
PLV- – – – – – – – – – – – – – – – CX – – XX – – – – – – – – – –
[1] Application (character 4-6) [6] PCB coating – IEC 721-3-3 (character 13) [10] Output filter (character 18)
302 VLT® AutomationDrive FC 302 C Coated PCB Class 3C3 X None
[2] Low harmonic filter option (character 7) R Coated PCB Class 3C3 + ruggedized D dV/dt
T None [7] Plinth (character 14) S Sine-wave
P Passive filter, THDi=5%, 50 Hz 1 100 mm high C Common mode
H Passive filter, THDi=8%, 50 Hz 2 200 mm high 1 Common mode + dV/dt
L Passive filter, THDi=5%, 60 Hz 3 400 mm high 2 Common mode + sine-wave
U Passive filter, THDi=8%, 60 Hz 4 Marine [11] Reserved (character 19)
[3] Mains voltage (character 8) [8] Braking and safety (character 15) X None
4 380 -480 V X No brake IGBT [12] Cable infeed option (character 20)
5 380-500 V B Brake IGBT X Bottom
7 525-690 V (UL 525-600 V) [9] Mains input (character 16-17) T Top
[4] Norms and standards (character 9) MX None L Mains top, motor bottom
I IEC M1 Fusible disconnect M Mains bottom, motor top
U UL M2 Non-fusible disconnect [13] Auxiliary Power Supply (character 21)
[5] Power size (character 10-12) M3 Circuit breaker (MCCB) 1 230 V AC External
90 90 kW / 125 Hp M4 Contactor 2 230 V AC Internal
110 110 kW / 150 Hp MA Fusible disconnect + contactor 4 230 V AC Internal+24 V DC Internal
132 132 kW / 200 Hp MB Non-fusible disconnect + contactor 5 230 V AC External+24 V DC Internal
160 160 kW / 250 Hp MC AC reactor + fusible disconnect 6 120 V AC External
200 200 kW / 300 Hp MD AC reactor + fusible disconnect + contactor 7 120 V AC Internal
250 250 kW / 350 Hp ME AC reactor + non-fusible disconnect 8 120 V AC Internal+24 V DC Internal
315 315 kW / 450 Hp MF AC reactor + circuit breaker (MCCB) 9 120 V AC External+24 V DC Internal
355 355 kW / 500 Hp MG AC reactor + contactor [14] Back-channel cooling option (character 22)
400 400 kW / 550 Hp AC reactor + non-fusible disconnect + X Bottom in, top out
MH
450 450 kW / 600 Hp contactor 1 Back in, back out
500 500 kW / 650 Hp C Back in, top out
560 560 kW / 750 Hp D Bottom in, back out
630 630 kW / 900 Hp N None
710 710 kW / 1000 Hp [15] Auxiliary functional option (character 23-24)
AX No auxiliary options
A1 AC socket+cabinet light
A2 Extended I/O terminals
A3 Cabinet heater
A4 Motor heater control
A5 Insulation monitor
AC socket+cabinet light
AA + extended I/O terminals
AB AC socket+cabinet light + cabinet heater
AC socket+cabinet light
AC + motor heater control
AD AC socket+cabinet light + insulation monitor
PLV- – – – – – – – – – – – – – – – CX – – XX – – – – – – – – – –
AC socket+cabinet light + extended I/O [18] Door-mounted option (character 28-29) [22] C1-option (character 33)
AE terminals + cabinet heater XX None X No option
AC socket+cabinet light + extended I/O D1 Signal lights and reset button R VLT® Extended Relay Card MCB 113
AF terminals + motor heater control
D2 Emg switch off and Emg-PB 7 VLT® Sensorless Safety MCB 159
AC socket+cabinet light + extended I/O
AG D3 STO w/ Emg-PB (no functional safety) [23] C-option software (character 34)
terminals + insulation monitor
D4 STO/SS1 w/ EM-PB+SLS (TTL Enc) No software option
AC socket+cabinet light + extended I/O Note: C4 option in [16] selected with no motion
AH terminals + cabinet heater + motor heater D5 STO/SS1 w/ EM-PB+SLS (HTL Enc) X
software in [18] will require programming by
control qualified individual
Signal lights and reset button + Emg switch
AC socket+cabinet light + extended I/O DA off and Emg-PB
AI terminals + cabinet heater + insulation 0 VLT® Synchronizing Controller MCO 350
monitor Signal lights and reset button (must select C4 in position [16])
DB
AC socket+cabinet light + extended I/O + STO w/ Emg-PB (no functional safety)
VLT® Positioning Controller MCO 351
AJ terminals + motor heater control + insulation 1 (must select C4 in position [16])
Signal lights and reset button + STO/SS1
monitor DC w/EM-PB+SLS (TTL Enc)
[24] D-option (character 35)
AC socket+cabinet light + extended I/O Signal lights and reset button + STO/SS1
AK terminals + cabinet heater + motor heater DE X No option
w/EM-PB+SLS (HTL Enc)
control + insulation monitor 0 VLT® 24 V DC Supply Option MCB 107
[19] A-options: Fieldbus (character 30)
AC socket+cabinet light + cabinet heater + 1 VLT® Real-time Clock Option MCB 117
AL X No option
motor heater control [25] EMC filter (character 36)
0 VLT® PROFIBUS DP MCA 101
AC socket+cabinet light + cabinet heater + 2 (H2) RFI class A2 (C3)
AM insulation monitor 4 VLT® DeviceNet MCA 104
4 (H4) RFI class A1 (C2)
AC socket+cabinet light + cabinet heater + 6 VLT® CANopen MCA 105
AN 6 IT Grid
motor heater control + insulation monitor T VLT® 3000 PROFIBUS Converter MCA 113
[26] Reserved (character 37)
AC socket+cabinet light + motor heater U VLT® 5000 PROFIBUS Converter MCA 114
AO control + insulation monitor X None
L VLT® PROFINET MCA 120
AP Extended I/O terminals + cabinet heater [27] Reserved (character 38-39)
N VLT® EtherNet/IP MCA 121
AQ Extended I/O terminals + motor heater control XX None
Q VLT® Modbus TCP MCA 122
AR Extended I/O terminals + insulation monitor [28] Documentation language (character 40)
Y VLT® POWERLINK MCA 123
Extended I/O terminals + cabinet heater + X English only
AS 8 VLT® EtherCAT MCA 124
motor heater control G English + German
V VLT® 5000 DeviceNet Converter MCA 194
Extended I/O terminals + cabinet heater + F English + French
AT insulation monitor [20] B-options (character 31)
X No application option Please beware that not all combinations are possible.
Extended I/O terminals + cabinet heater + Find help configuring your drive with the online
AU motor heater control + insulation monitor K VLT® General Purpose MCB 101 configurator found under: driveconfig.danfoss.com
Extended I/O terminals + motor heater control R VLT® Encoder Input MCB 102
AV + insulation monitor
U VLT® Resolver Input MCB 103
AW Cabinet heater + motor heater control
P VLT® Relay Option MCB 105
A8 Cabinet heater + insulation monitor
Z VLT® Safety PLC I/O MCB 108
Cabinet heater + motor heater control +
AY 2 VLT® PTC Thermistor Card MCB 112
insulation monitor
AZ Motor heater control + insulation monitor 4 VLT® Sensor Input Card MCB 114
[16] LCP display (character 25) 5 VLT® Programmable I/O MCB 115
[17] Enclosure rating (character 26-27) 8 VLT® Safety Option MCB 152 PROFIsafe STO
21 IP21 [21] C0-option (character 32)
54 IP54 X No option
4 VLT® Motion Control MCO 305
The VLT® 5000 can be replaced by the VLT® EtherNet/IP MCA 121
VLT® AutomationDrive, or an existing system
can be expanded without costly change of the Order code
PLC program. 130B1119 standard, dual-port
130B1219 coated, dual-port
The option supports DPV1.
Order code
130B1246 coated
Order code
130B1489 standard, dual-port
130B1490 coated, dual-port
VLT® General Purpose I/O VLT® Relay Card MCB 105 VLT® Analog I/O Option
MCB 101 Makes it possible to extend relay functions with MCB 109
3 additional relay outputs.
This I/O option offers an extended number of This analog input/output option is easily fitted
control inputs and outputs: in the AC drive for upgrading to advanced
Max. switch rate at rated performance and control using the additional
load/min. load ................................ 6 min-1/20 sec-1
3 digital inputs 0-24 V: Logic ‘0’ < 5 V; Logic I/O. This option also upgrades the AC drive with
Protects control cable connection
‘1’ > 10V a battery back-up supply for the AC drive built-
Spring-loaded control wire connection
2 analog inputs 0-10 V: Resolution 10 bit in clock. This provides stable use of all AC drive
plus sign clock functions as timed actions.
Max. terminal load:
2 digital outputs NPN/PNP push pull AC-1 Resistive load ............................ 240 V AC 2 A
1 analog output 0/4-20 mA 3 analog inputs, each configurable as both
AC-15 Inductive
Spring-loaded connection voltage and temperature input
load @cos phi 0.4 ............................240 V AC 0.2 A Connection of 0-10 V analog signals as well
DC-1 Resistive load ...............................24 V DC 1 A
Ordering number as Pt1000 and Ni1000 temperature inputs
DC-13 Inductive
130B1125 standard 3 analog outputs each configurable as 0-10
load @cos phi 0.4 .............................. 24 V DC 0.1 A
130B1212 coated (Class 3C3/IEC 60721-3-3) V outputs
Back-up supply for the standard clock func-
Min. terminal load: tion in the AC drive
DC 5 V........................................................................10 mA
VLT® Encoder Input MCB 102 The back-up battery typically lasts for 10 years,
Ordering number
This option offers the possibility to connect depending on environment.
130B1110 standard
various types of incremental and absolute 130B1210 coated (Class 3C3/IEC 60721-3-3)
encoders. The connected encoder can be used Ordering number
for closed loop speed/position control as well 130B1143 standard
as closed loop flux motor control. 130B1243 coated (Class 3C3/IEC 60721-3-3)
VLT® Safe PLC I/O MCB 108
The following encoder types are supported: The VLT® AutomationDrive FC 302 provides a
5V TTL (RS 422) safety input based on a single-pole 24 V DC
1VPP SinCos VLT® PTC Thermistor Card
input.
SSI
Hiperface For the majority of applications, this input
MCB 112
EnDat 2.1 and 2.2 enables the user to implement safety in a The VLT® PTC Thermistor Card
cost-effective way. For applications that MCB 112 enables improved surveillance of the
Ordering number work with more advanced products like motor condition compared to the built-in ETR
130B1115 standard Safety PLC and light curtains, the Safe PLC function and thermistor terminal.
130B1203 coated (Class 3C3/IEC 60721-3-3) interface enables the connection of a two-
wire safety link Protects the motor from overheating
The Safe PLC Interface allows the Safe PLC ATEX-approved for use with Ex d and
VLT® Resolver Input MCB 103 to interrupt on the plus or the minus link Ex e motors
without interfering the sense signal of the Uses Safe Torque Off function, which is
This option enables connection of a resolver to Safe PLC approved in accordance with SIL 2 IEC 61508
provide speed feedback from the motor.
Ordering number Ordering number
Primary voltage............................................. 2-8 Vrms 130B1120 standard 130B1137 coated (Class 3C3/IEC 60721-3-3)
Primary frequency.................................... 2.0-15 kHz 130B1220 coated (Class 3C3/IEC 60721-3-3)
Primary current max...............................50 mA rms
Secondary input voltage.............................4 Vrms
Spring-loaded connection
Ordering number
130B1127 standard
130B1227 coated (Class 3C3/IEC 60721-3-3)
Ordering number
130B3280 MCB 150, 130B3290 MCB 151
Ordering number
130B1134 standard
130B1234 coated (Class 3C3/IEC 60721-3-3)
VLT® Sine-wave Filter VLT® Common Mode Filter VLT® Brake Resistor MCE 101
MCC 101 MCC 105 Energy generated during braking is
absorbed by the resistors, protecting
VLT® Sine-wave Filters are positioned bet- Positioned between the AC drive and the electrical components from heating up
ween the AC drive and the motor to provide motor Optimized for the FC-series and general
a sinusoidal phase-to-phase motor voltage They are nano-crystalline cores that mitigate versions for horizontal and vertical motion
Reduces motor insulation stress high-frequency noise in the motor cable are available
Reduces acoustic noise from the motor (shielded or unshielded) and reduce bearing Built-in thermo switch
Reduces bearing currents (especially in large currents in the motor Versions for vertical and horizontal
motors) Extends motor bearing lifetime mounting
Reduces losses in the motor Can be combined with dU/dt and sine-wave A selection of the vertically mounted units
Prolongs service lifetime filters are UL-recognized
VLT® FC series family look Reduces radiated emissions from the motor
cable Power range
Power range Reduces electromagnetic interference Precision electrical match to each individual
3 x 200-500 V, 2.5-800 A Easy to install – no adjustments necessary VLT® drive power size
3 x 525-690 V, 4.5-660 A Oval shaped – allows mounting inside the
AC drive enclosure or motor terminal box Enclosure ratings:
Enclosure ratings IP20
IP00 and IP20 wall-mounted enclosures Power range IP21
rated up to 75 A (500 V) or 45 A (690 V) 380-415 V AC (50 and 60 Hz) IP54
IP23 floor-mounted enclosures rated 115 A 440-480 V AC (60 Hz) IP65
(500 V) or 76 A (690 V) or more 600 V AC (60 Hz)
IP54 both wall-mounted and floor-mounted 500-690 V AC (50 Hz) Ordering number
enclosures rated up to 4.5 A, 10 A, See relevant Design Guide
22 A (690 V) Ordering number
130B3257 Enclosure size A and B
Ordering number 130B7679 Enclosure size C1
See relevant Design Guide 130B3258 Enclosure size C2, C3 and C4 VLT® Line Reactor MCC 103
130B3259 Enclosure size D
130B3260 Enclosure size E and F Ensures current balance in load-sharing ap-
plications, where the DC-side of the rectifier
VLT® dU/dt Filter MCC 102 of multiple drives is connected together
UL-recognized for applications using load
Reduces the dU/dt values on the motor VLT® Advanced Harmonic sharing
terminal phase-to-phase voltage
Filter AHF 005 and AHF 010 When planning load-sharing applications,
Positioned between the AC drive and the pay special attention to different enclosure
motor to eliminate very fast voltage chan- Optimized harmonic performance for type combinations and inrush concepts
ges VLT® drives rated up to 250 kW For technical advice regarding load-sharing
The motor terminal phase-to-phase voltage A patented technique reduces THD levels in applications, contact Danfoss application
is still pulse shaped but its dU/dt values are the mains network to less than 5-10% support
reduced Perfect match for industrial automation, Compatible with VLT® AutomationDrive
Reduces stress on the motor’s insulation highly dynamic applications and safety 50 Hz or 60 Hz mains supply
and are recommended in applications with installations
older motors, aggressive environments or Intelligent cooling with variable-speed fan Ordering number
frequent braking which cause increased DC See relevant Design Guide
link voltage Power range
VLT® FC series family look 380-415 V AC (50 and 60 Hz)
440-480 V AC (60 Hz)
Power range 600 V AC (60 Hz)
3 x 200-690 V (up to 880 A) 500-690 V AC (50 Hz)
Enclosure ratings Enclosure ratings
IP00 and IP20/IP23 enclosure in the entire IP20
power range (An IP21/NEMA 1 upgrade kit is available)
IP54 enclosure available up to 177 A
Ordering number
Ordering number See relevant Design Guide
See relevant Design Guide
Fuses 9 – n
Optional
n Standard
Ordering number
F1/F2, 400 mm.....................................................176F1832
F1/F2, 600 mm.....................................................176F1833
Ordering number
D1h 400 mm kit.................................................. 176F3631
D2h 400 mm kit.................................................. 176F3632 Multi-wire kit Tall pedestal kit
D5h/D6h 200 mm kit......................................176F3452 The kit is designed to connect the drive with The tall pedestal kit contains all parts required
D7h/D8h 200 mm kit...................................... 176F3539 multi-wire cable for each motor phase or mains to install the tall pedestal for E1h and E2h
E1h 400 mm kit...................................................176F6764 phase. drives. The tall pedestal is 400 mm (15.7 in) and
E2h 400 mm kit.................................................. 176F6763 replaces the standard pedestal that ships with
Ordering number the drive.
D1h..............................................................................176F3817
Input-plate option kit D2h............................................................................. 176F3818 Ordering number
Tall pedestal kit for E1h..................................176F6764
Input-plate option kits are available for enclo- Tall pedestal kit for E2h...................................176F6763
sure sizes D and E. The kits can be ordered to
add fuses, disconnect/fuses, RFI, RFI/fuses and L-shaped busbar kit
RFI/disconnect/fuses. Please consult the factory The kit allows multi-wires mounting for each
for kit ordering numbers. phase of mains or motor. D1h, D3h drives can
Cable clamp kit
have 3 connections per phase of 50 mm2 and The kit includes all parts required to install
D2h, D4h can accommodate 4 connections per cable clamps for mains, motor, and control
Top entry of fieldbus cables phase of 70 mm2. wiring.
The top entry kit provides the ability to install Ordering number Ordering number
fieldbus cables through the top of the drive. D1h/D3h L-shaped motor E3h.............................................................................. 176F6746
The kit is IP20 when installed. If an increased busbars kit..............................................................176F3812 E4h...............................................................................176F6747
rating is desired, a different mating connector D2h/D4h L-shaped motor
can be used. busbars kit............................................................. 176F3810
D1h/D3h L-shaped mains
Ordering number busbars kit.............................................................176F3854
D1h-D8h..................................................................176F3594 D2h/D4h L-shaped mains
busbars kit............................................................. 176F3855