AF116-30-00-13 1/6

PRODUCT-DETAILS

AF116-30-00-13
AF116-30-00-13 Contactor

General Information
Extended Product Type AF116-30-00-13
Product ID 1SFL427001R1300
EAN 7320500476406
Catalog Description AF116-30-00-13 Contactor
The AF116-30-00-13 is a 3 pole - 690 V IEC or 600 V UL contactor with double clamp,
controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power
circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the
contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large
Long Description
control voltage variations, reducing panel energy consumptions and ensuring distinct
operations in unstable networks. Furthermore, surge protection is built-in, offering a compact
solution. AF contactors have a block type design, can be easily extended with add-on
auxiliary contact blocks and an additional wide range of accessories.

Ordering
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Popular Downloads

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice
AF116-30-00-13 2/6

Data Sheet, Technical 1SBC100214C0202


Information
Instructions and Manuals 1SFC100003M0201
CAD Dimensional 2CDC001079B0201
Drawing
Dimension Diagram 1SFB535001G1051

Dimensions
Product Net Width 90 mm
Product Net Depth / 126 mm
Length
Product Net Height 150 mm
Product Net Weight 1.55 kg

Technical
Number of Main Contacts 3
NO
Number of Main Contacts 0
NC
Number of Auxiliary 0
Contacts NO
Number of Auxiliary 0
Contacts NC
Rated Operational Voltage Main Circuit 690 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Thermal Current (I th )
Rated Operational Current (690 V) 40 °C 160 A
AC-1 (I e ) (690 V) 60 °C 145 A
(690 V) 70 °C 130 A
Rated Operational Current (415 V) 55 °C 116 A
AC-3 (I e ) (440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current (415 V) 60 °C 116 A
AC-3e (I e ) (440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
Rated Operational Power (415 V) 55 kW
AC-3 (P e ) (440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Operational Power (415 V) 55 kW
AC-3e (P e ) (440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity 8 x Ie AC-3
AC-3
Rated Breaking Capacity 8.5 x Ie AC-3e
AC-3e
Rated Making Capacity 10 x Ie AC-3
AC-3
Rated Making Capacity 12 x Ie AC-3e
AC-3e
Short-Circuit Protective gG Type Fuses 250 A
Devices

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice
AF116-30-00-13 3/6

Rated Short-time at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
Withstand Current Low at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
Voltage (I cw ) at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Breaking cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
Maximum Electrical (AC-1) 300 cycles per hour
Switching Frequency (AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current (110 V) 2 Poles in Series, 40 °C 145 A
DC-1 (I e ) (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current (110 V) 2 Poles in Series, 40 °C 145 A
DC-3 (I e ) (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current (110 V) 2 Poles in Series, 40 °C 145 A
DC-5 (I e ) (220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
(U i ) acc. to UL/CSA 600 V
Rated Impulse Withstand Main Circuit 8 kV
Voltage (U imp )
Mechanical Durability 5 million
Maximum Mechanical 300 cycles per hour
Switching Frequency
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit 50 Hz 100 ... 250 V
Voltage (U c ) 60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Operate Time Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Flexible 2 x 10 ... 70 mm²
Circuit Rigid Cu-Cable 1 x 10 ... 95 mm²
Connecting Capacity Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Auxiliary Circuit Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Double Clamp

Technical UL/CSA
Maximum Operating Main Circuit 600 V
Voltage UL/CSA
General Use Rating (600 V AC) 160 A
UL/CSA
Horsepower Rating (200 V AC) Three Phase 30 hp
UL/CSA (208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp

Environmental
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Without Derating 3000 m
Altitude Permissible

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice
AF116-30-00-13 4/6

Material Compliance
Conflict Minerals 9AKK108467A5658
Reporting Template
(CMRT)
REACH Declaration 2CMT2021-006202
RoHS Information 2CMT2021-006277
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control 2CMT2023-006525
Act - TSCA
WEEE B2C / B2B Business To Business
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
ABB EcoSolutions Yes
Environmental Product 1SFC100092D0201
Declaration - EPD
Circular Design Principles Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Recyclability Rate
Sustainable Material Recycled Metal - 37 %
Content
Group Waste to Landfill Non-hazardous waste is sent to a landfill, where there is no alternative option
Target available within 100km of a facility
Improved Resource Product Efficiency - Product requires less energy to operate compared to
Efficiency for Customers similar product on market or older products from the same line
End of Life Instructions 1SFC100112M0001

Certificates and Declarations


A2L Certificate – UL 9AKK108468A6693
ABS Certificate 14-LD1092198-PDA
BV Certificate BV_36353_A0BV
CB Certificate SEMKO_SE-70479M1
CCS Certificate GB14T00030
CQC Certificate CQC2013010304604055
Declaration of Conformity 2020980304001304
- CCC
Declaration of Conformity 2CMT2015-005439
- CE
Declaration of Conformity 2CMT2020-006118
- UKCA
DNV Certificate DNV_E-14043
EAC Certificate 9AKK107046A8618
LR Certificate LR_14_70011(E1)
PRS Certificate TE_2092_880423_16
RINA Certificate ELE060313XG_002
RMRS Certificate 9AKK107045A6978
UL Certificate 20120925-E36588
UL Listing Card UL_E36588

Container Information
Package Level 1 Units box 1 piece
Package Level 1 Width 207 mm
Package Level 1 Depth / 216 mm
Length
Package Level 1 Height 150 mm
Package Level 1 Gross 1.75 kg
Weight

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice
AF116-30-00-13 5/6

Package Level 1 EAN 7320500476406

Classifications
Object Classification Code Q
ETIM 7 EC000066 - Power contactor, AC switching
ETIM 8 EC000066 - Power contactor, AC switching
ETIM 9 EC000066 - Power contactor, AC switching
eClass V11.0 : 27371003
UNSPSC 39121529
IDEA Granular Category 4758 >> Iec Contactors
Code (IGCC)
E-Number (Finland) 3706166
E-Number (Norway) 3210062
E-Number (Sweden) 3210062

Accessories
Unit Of
Identifier Description Type Quantity
Measure
1SFN034403R1000 VM140/190 Mechanical Interlock Unit VM140/190 1 piece
1SFN074203R1000 LY140 Connecting Strip LY140 1 piece
1SFN074207R1000 LW140 Terminal Enlargement LW140 1 piece
1SFN074208R1000 LD146-30 Connection Module LD146-30 1 piece
1SFN074210R1000 LX140 Terminal Extension LX140 1 piece
1SFN074211R1000 LL146-30 Connection Socket LL146-30 1 piece
1SFN084206R1000 BEA140/XT2 Connection Set BEA140/XT2 1 piece
1SFN084206R1001 BEA140/XT4 Connection Set BEA140/XT4 1 piece
1SFN084206R1002 BEA140/XT3 Connection Set BEA140/XT3 1 piece
1SFN084211R1000 BER140-4 Connection Set BER140-4 1 piece
1SFN084214R1000 BEP140-30 Connection Set BEP140-30 1 piece
1SFN084413R1000 BEY140-4 Connection Set BEY140-4 1 piece
1SFN094200R1000 PR146-1 Adapter Plate PR146-1 1 piece
1SFN124203R1000 LT140-30L Terminal Shroud LT140-30L 1 piece
1SFN074208R2000 LD146-40 Connection Module LD146-40 1 piece
1SFN074211R2000 LL146-40 connection sockets kit LL146-40 1 piece
1SFN084214R2000 BEP140-40 Connection Set BEP140-40 1 piece
1SFN124203R2000 LT140-40L Terminal Shroud LT140-40L 1 piece

Categories
Low Voltage Products and Systems → Control Products → Contactors → Block Contactors → AF Contactors → AF116

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice
AF116-30-00-13 6/6

© 2024 ABB. All rights reserved. 2024/10/13 Subject to change without notice

You might also like