0% found this document useful (0 votes)
81 views2 pages

FC280

The VLT® Midi Drive FC 280 is a versatile AC drive designed for various applications such as conveyor systems, pumps, and compressors, featuring integrated components that simplify installation and reduce costs. It offers advanced functionalities like harmonic mitigation, dual-channel Safe Torque Off, and flexible fieldbus communication, making it suitable for industries like food and beverage and material handling. The drive is easy to retrofit, supports efficient motor control, and includes user-friendly features for commissioning and troubleshooting.

Uploaded by

db.controlsystem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views2 pages

FC280

The VLT® Midi Drive FC 280 is a versatile AC drive designed for various applications such as conveyor systems, pumps, and compressors, featuring integrated components that simplify installation and reduce costs. It offers advanced functionalities like harmonic mitigation, dual-channel Safe Torque Off, and flexible fieldbus communication, making it suitable for industries like food and beverage and material handling. The drive is easy to retrofit, supports efficient motor control, and includes user-friendly features for commissioning and troubleshooting.

Uploaded by

db.controlsystem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Fact Sheet

VLT® Midi Drive FC 280


Flexible. Communicative. Easy to use.

The right mix of features ensures the Integrated features free you from
AC drive suits your task, whether for finding space and budget to install
conveyor systems, mixers, and packag- extra components:
ing systems or driving pumps, fans, and
compressors. n Harmonic mitigation
n RFI filter
VLT® Midi Drive saves installation time, n Dual-channel Safe Torque Off (STO)
with all pluggable connectors, and USB n Brake chopper
port for convenient PC connection. For
easy and intelligent commissioning, Product range
transfer, or programming of factory 3 x 380-480 V ...................................0.37-22 kW
settings, use the handy VLT® Memory 3 x 200-240 V ..................................0.37-3.7 kW
Module. 1 x 200-240 V ..................................0.37-2.2 kW
Set-up wizards simplify commissioning
for common applications.
Access your true high-efficiency
potential with the VLT® Midi Drive Feature Benefit
FC 280, the evolution of the popular Integrated harmonics and EMC design
VLT® 2800 drive. Profit from new sav- – Saves installation time and panel space
Integrated DC choke or active power factor requirements
ings, with a wide range of features correction (PFC) – Improves power supply quality
designed to make installing, using, – Reduces effective input current/VA rating
and maintaining the drive as simple – Avoids malfunction and improves reliability
of surrounding components
and as easy as possible – just set and – Saves installation time and panel space
Integrated EMC filter
forget. requirements
– Proven compliance to Cat. C2/EN 61800-3
(Class A1/EN 55011)
This AC drive delivers precise and RFI switch – Operates safely on IT mains
efficient motor control for machine Easy to install and set up
builders in the food and beverage, Pluggable terminals – Fast installation and unit exchange
material handling, and processing – Easy PC connection for troubleshooting
industries. It is strong on control perfor- USB port or commissioning
– No need for adapter or PC-USB driver
mance, functional safety, and flexible
Application set-up wizards – Easy commissioning
fieldbus communication. Enhanced numerical LCP (option) – Cost effective user interface
Graphical LCP supporting various languages, – Easy set-up in one of seven main languages
It’s also an easy retrofit for the including adapter (option) – Fast troubleshooting
VLT® 2800 in established plant or – Convenient transfer of parameter set-up
machinery concepts. Memory module (option) – Easy firmware updates
– Easy and fast commissioning
– Convenient transfer files to and from the
Memory module reader (option) VLT® Memory Module MCM 102 via PC
Strategic design for applications, safety, and motor control
– Eliminates external components
Integrated Safe Torque Off (STO), dual channel
Active power factor – Enables reliable functional safety
correction for single- Control algorithm runs both – Freedom to choose the best
phase units reduces induction and PM motors high-efficiency motor for the task
harmonics to less Integrated brake chopper for 3-phase drives in all – No cost for external braking chopper
than power sizes up to 22 kW
Side-by-side or horizontal mounting, without – Allows flexible mounting and saves cabinet

8% THDi
derating and clearance
Operates at up to 45 °C without derating and
clearance
space and cost
– Saves cost for external cooling and reduces
downtime for overtemperature failures

drives.danfoss.com
Integrated harmonic mitigation Specifications
In compliance with IEC/EN 61000-3-2/ Mains supply (L1, L2, L3)
61000-3-12, the integrated DC chokes 200-240 V (-15%/+10%)
Supply voltage
for all 3-phase units reduce harmonics 380-480 V (-15%/+10%)
to less than 48% THDi. Supply frequency 50/60 Hz
For single-phase units the harmonics Displacement power factor (cos φ) Near unity (> 0.98)
are less than 8% thanks to the Switching frequency on input supply L1, L2, L3 Switching maximum 2 times/minute
Output data (U, V, W)
integrated active PFC.
Output voltage 0-100% of supply voltage
Switching on output Unlimited
Integrated RFI filter
Ramp times 0.01-3600 s
Built-in filters not only save space, but
Frequency range 0-500 Hz
also eliminate extra costs for fitting,
Programmable digital inputs and outputs
wiring and material.
Digital inputs / digital outputs* 6 (7) / 1
Logic PNP or NPN
Dual-channel Safe Torque Off
Voltage level 0-24 V DC
The Safe Torque Off (STO) function is a One of 6 digital inputs can be configured as digital output or pulse output. One of analog inputs can be config-
component in a safety control system. ured as an extra digital input, thereby bring the quantity of digital inputs to 7.
STO prevents the unit from generating Pulse and encoder inputs
the energy that is required to rotate the Pulse inputs / encoder inputs** 2/2
motor, which ensures safe conditions in Voltage level 0-24 V DC
emergency situations. **Note: Two digital inputs can be configured as pulse inputs.
One pair of inputs can be configured as encoder inputs.
Programmable analog inputs
PM motor compatibility
Analog inputs 2
The VLT® Midi Drive provides highly
1 voltage or current /
efficient permanent magnet (PM) Modes 1 voltage or DI
motor control in open loop under Voltage level 0 V to +10 V (scaleable)
V VC+ in the whole power range. Current level 0/4 to 20 mA (scaleable)
Programmable analog outputs
Your choice of fieldbus Analog outputs 1
n PROFINET with dual port Current range at analog output 0/4 to 20 mA
n POWERLINK with dual port Programmable relay outputs
n EtherNet/IP™ with dual port Relay outputs 1
n PROFIBUS Approvals
n CANopen Approvals CE, UL listed, cUL, TÛV, RCM (C-Tick), EAC
n Modbus RTU and FC Protocol are b

integrated as standard
B C

The optional 24 V DC back-up Easy connectivity


A a
power supply keeps the fieldbus For convenient PC connection during
communication on, while disconnected commissioning or service, use the
from mains. integrated USB port.

Dimensions and weights


Enclosure IP20 K1 K2 K3 K4 K5
Single-phase 200-240 V 0.37 0.55 0.75 1.1 1.5 2.2
Power size
[kW] 3-phase 200-240 V 0.37 0.55 0.75 1.1 1.5 2.2 3.7
3-phase 380-480 V 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22
Height A 210 272.5 272.5 320 410
EtherNet/IP™ and DeviceNet™ are trademarks of ODVA, Inc.

Dimensions Width B 75 90 115 135 150


[mm]
Depth C 168 168 168 245 245
Mounting a 198 260 260 297.5 390
holes b 60 70 90 105 120
Weight [kg] IP20 2.3 2.5 3.6 4.1 9.4 9.5 12.3 12.5

Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, drives.danfoss.com, E-mail: [email protected]

DKDD.PFP.820.A7.02 © Copyright Danfoss Drives | 2017.06